SYNTHETIC/EXPLORATORY four_chamber_m1

not clinically validated; no atrial contraction, AV delay, inertance, closure regurgitation, valve area/FSI, septal/pericardial coupling, renal or drug models. Fixed cycles do not prove steady state. No Smith or published four-chamber reference reproduction. Sampled EDV/ESV/EF describe volume excursion; they need not equal ejection throughput during overlap or transients.

Final beat pressures, volumes, PV loops and flows

Trajectories · Summary · Semantic contract and provenance

{
  "conservation": {
    "local_balance_residual_ml": 1.7280399333685637e-11,
    "total_initial_volume_ml": 5120.0,
    "total_volume_drift_ml": 1.0913936421275139e-11
  },
  "limitations": "not clinically validated; no atrial contraction, AV delay, inertance, closure regurgitation, valve area/FSI, septal/pericardial coupling, renal or drug models. Fixed cycles do not prove steady state. No Smith or published four-chamber reference reproduction. Sampled EDV/ESV/EF describe volume excursion; they need not equal ejection throughput during overlap or transients.",
  "metric_semantics": "SV/CO use integrated outlet flows; EDV/ESV/EF use sampled extrema. Pressure/volume means use sampled time quadrature.",
  "metrics": {
    "la_pressure_max_mmhg": 8.702371541802197,
    "la_pressure_mean_mmhg": 6.658808584243309,
    "la_pressure_min_mmhg": 5.462288217352229,
    "la_volume_max_ml": 78.01581027868131,
    "la_volume_mean_ml": 64.39205722828873,
    "la_volume_min_ml": 56.41525478234819,
    "lv_cardiac_output_l_min": 4.462357345370732,
    "lv_cardiac_output_ml_s": 74.37262242284554,
    "lv_edv_sample_ml": 109.0002411840834,
    "lv_ejection_fraction_sample": 0.5458529017178426,
    "lv_esv_sample_ml": 49.50214324580678,
    "lv_stroke_volume_ml": 59.49809793827649,
    "pa_pressure_max_mmhg": 23.202954816356296,
    "pa_pressure_mean_mmhg": 17.814744502028745,
    "pa_pressure_min_mmhg": 13.662900394985337,
    "ra_pressure_max_mmhg": 4.954113078981488,
    "ra_pressure_mean_mmhg": 3.5684377240919676,
    "ra_pressure_min_mmhg": 2.8934821693472417,
    "ra_volume_max_ml": 69.54113078981487,
    "ra_volume_mean_ml": 55.684377240919666,
    "ra_volume_min_ml": 48.934821693472415,
    "rv_cardiac_output_l_min": 4.462377438210337,
    "rv_cardiac_output_ml_s": 74.37295730350563,
    "rv_edv_sample_ml": 98.79278981072407,
    "rv_ejection_fraction_sample": 0.6022541316709119,
    "rv_esv_sample_ml": 39.29442396791953,
    "rv_stroke_volume_ml": 59.49836584280456,
    "sa_pressure_max_mmhg": 98.83589515896088,
    "sa_pressure_mean_mmhg": 81.6593524632826,
    "sa_pressure_min_mmhg": 64.95807712812673
  },
  "model_id": "four_chamber_m1",
  "model_version": "1.0.0",
  "null_policy": "Unavailable periodicity for a single beat is null.",
  "parameters": {
    "compliance_pa": 5.0,
    "compliance_pv": 20.0,
    "compliance_sa": 1.5,
    "compliance_sv": 100.0,
    "elastance_la": 0.15,
    "elastance_ra": 0.1,
    "emax_lv": 2.5,
    "emax_rv": 0.8,
    "emin_lv": 0.06,
    "emin_rv": 0.03,
    "heart_rate": 75.0,
    "initial_volumes": [
      140.0,
      850.0,
      3200.0,
      60.0,
      140.0,
      180.0,
      490.0,
      60.0
    ],
    "resistance_aortic": 0.01,
    "resistance_mitral": 0.01,
    "resistance_pulmonary": 0.1,
    "resistance_pulmonary_valve": 0.01,
    "resistance_pulmonary_venous": 0.05,
    "resistance_systemic": 1.0,
    "resistance_tricuspid": 0.01,
    "resistance_venous_return": 0.05,
    "systolic_fraction": 0.4,
    "unstressed_volumes": [
      10.0,
      700.0,
      2500.0,
      20.0,
      10.0,
      100.0,
      400.0,
      20.0
    ]
  },
  "periodicity": {
    "interpretation": "Fixed cycle count does not prove steady state; sampled final/prior beat differences only.",
    "max_difference_ml": 0.0007067402634675091,
    "per_compartment_ml": {
      "la": 6.79322103920299e-05,
      "lv": 0.00024889087241319885,
      "pa": 5.986735700957979e-05,
      "pv": 0.00016198836647163262,
      "ra": 4.872229416719165e-05,
      "rv": 0.00010317636377976669,
      "sa": 0.00044498443526208575,
      "sv": 0.0007067402634675091
    }
  },
  "pressure_reference": "model gauge pressure relative to one common fixed external pressure of 0 mmHg; no intrathoracic/pericardial pressure",
  "provenance": "SYNTHETIC/EXPLORATORY test-design values; not literature-derived, not fitted, not normal physiology. Ventricular/vascular scalars reuse legacy exploratory defaults; new atrial and venous-inflow values are test-design choices. Explicit caller total: 5120 mL.",
  "settings": {
    "atol": 1e-10,
    "max_step": 0.004,
    "method": "DOP853",
    "rtol": 1e-09
  },
  "simulation": {
    "cycles": 30,
    "samples_per_cycle": 400
  }
}