four_chamber_m1 1.0.0 — passive atria

SYNTHETIC/EXPLORATORY research software; not clinically validated. No patient information, physiological calibration or published four-chamber reproduction. Legacy six-compartment equations, identities and experiments remain independent.

Numerical acceptance criteria (declared before implementation/test execution)

Check Absolute bound Rationale
Total volume drift 1e-7 mL Linear invariant, roundoff at ~5000 mL and short runs
Local balance residual 1e-6 mL Augmented linear invariant; wiring/roundoff only, not quadrature accuracy
Passive analytic subproblem 1e-6 mL expm solution, rtol/atol 1e-10; short 0.5 s interval
DOP853 tolerance refinement 1e-5 mL Compare volumes and integrals, 1e-9/1e-10 T/200 vs 1e-11/1e-12 T/400, 3 beats
Radau vs DOP853 1e-4 mL Independent integration methods, 1e-10/1e-10, 2 beats
Large-step pulse 1e-4 mL volumes; 1e-5 mL integrals Resolving peak must prevent missing an entire opening
Simultaneous symmetric circuits 1e-7 mL volumes; 1e-6 mL integrals Symmetry with roundoff-scale event ordering differences
Sampling independence, replay, equilibrium, output diode law Exact Sampling cannot change adaptive integration; law recomputed without approximations

These software bounds are fixed before observing results; no clinical target is used. Failures must be diagnosed, not hidden by relaxed thresholds.

Equations and contract

MODEL_ID="four_chamber_m1", version 1.0.0. State order is (lv, sa, sv, ra, rv, pa, pv, la). Every state is a total blood volume (mL), not a stressed volume. Caller-supplied V0 is the unstressed-volume parameter. The sum of the eight initial volumes declares the total; it is never normalized. There is no legacy volume-splitting/migration helper or anatomical identity claim.

Edge (column order) Source Target Law
aortic lv sa ideal diode
systemic sa sv signed resistor
venous_return sv ra signed resistor
tricuspid ra rv ideal diode
pulmonary_valve rv pa ideal diode
pulmonary pa pv signed resistor
pulmonary_venous pv la signed resistor
mitral la lv ideal diode

For each edge e, B[source,e]=-1, B[target,e]=+1, and every other entry is zero. Thus dV/dt = B q, 1^T B=0, and d(sum V)/dt=0. The versioned endpoint table is validated independently of conservation: swapping an edge can conserve mass and still violate M1's topology.

                  ao sys vr tc pv pul pvr mt
B (lv row)       = -1  0  0  0  0  0   0   1
  (sa)          =  1 -1  0  0  0  0   0   0
  (sv)          =  0  1 -1  0  0  0   0   0
  (ra)          =  0  0  1 -1  0  0   0   0
  (rv)          =  0  0  0  1 -1  0   0   0
  (pa)          =  0  0  0  0  1 -1   0   0
  (pv)          =  0  0  0  0  0  1  -1   0
  (la)          =  0  0  0  0  0  0   1  -1

With T=60/HR s and phi=(t mod T)/T, let s=systolic_fraction:

a(phi) = (1-cos(2*pi*phi/s))/2, if phi < s; 0 otherwise
E_v(t) = Emin_v + (Emax_v-Emin_v)*a(phi), v in {lv,rv}
P_v = E_v(t)*(V_v-V0_v), v in {lv,rv}
P_a = E_a*(V_a-V0_a), a in {la,ra}, constant positive E_a
P_i = (V_i-V0_i)/C_i, i in {sa,sv,pa,pv}
dp_e = P_source(e)-P_target(e)
q_e = max(dp_e/R_e,0), for the four ideal diodes
q_e = dp_e/R_e, for the four signed resistors
Cumulative_e(t) = integral from 0 to t of q_e(u) du

The ventricular activation calls the existing cardiovascular.elastance function; legacy code and behavior are unchanged. M1 has eight volume states plus eight auxiliary flow integrals. There is no flow/inertance state.

Pressure reference (exact machine contract): "model gauge pressure relative to one common fixed external pressure of 0 mmHg; no intrathoracic/pericardial pressure". This is a declared mathematical gauge, with no assertion about atmospheric or absolute pressure. All chambers/compartments share it; negative gauge pressures are allowed. No pressure/volume clipping or conservation projection is applied.

Quantity Unit
Time / maximum step s
Volume, initial/unstressed volume, cumulative flow, SV, solver atol mL
Pressure mmHg
Instantaneous flow / mean CO mL/s (CO also explicitly converted to L/min)
Elastance mmHg/mL
Compliance mL/mmHg
Resistance mmHg s/mL
HR beats/min
Activation, systolic fraction, EF, solver rtol dimensionless

Parameters have no defaults. All scalar physiology inputs must be real, finite, positive, with 0<s<1 and Emax>=Emin. Initial volumes are eight positive finite values, unstressed volumes eight nonnegative finite values. Caller lists become immutable tuples. Invalid shapes, booleans, non-real scalars and nonfinite values are rejected. Numerical controls live in the separate SolverSettings class.

Integration and reported quantities

The solver integrates fixed smooth valve regimes to terminal pressure-gap events, using a short forward probe to choose the right-hand mode at roundoff-scale ties. A signed epsilon sentinel prevents repeated events at identically zero gaps. Each beat splits at activation start, peak, end of systole and beat end. Only the portion of each dense interpolant preceding its first event is retained. Eight integrals restart at zero per regime and accumulate through offsets; solver rtol and atol apply unchanged to physical volumes and local integral increments.

Terminal zero-volume events and checks on accepted nodes/sampled dense output raise explicit failures. Solver failure, uncovered samples, nonfinite state and repeated failure to advance also raise. There is no silent repair or tolerance change. Extremely large/ill-conditioned explicit inputs may fail numerically; these are not guaranteed admissible physiological configurations.

FourChamberM1Result contains named columns for time, volumes, pressures, flows and cumulative flows. Outputs recompute the exact algebraic flow law from the reported pressure, rather than storing a regime-dependent approximate diode law. volume(name), pressure(name) and flow(name) expose columns.

The final-beat metrics use cumulative aortic/pulmonary-valve differences for LV/RV forward SV (mL) and divide by beat duration for CO (mL/s and L/min). EDV/ESV are sampled maximum/minimum volumes, with EF their fractional excursion; they are not event-defined or a guarantee of integrated ejection fraction. During inflow/outflow overlap or transients, the volume excursion need not equal forward SV. Atrial pressure/volume min/max and time means are included, as are SA/PA min/max/mean pressure. Means use sampled trapezoidal quadrature and extrema can depend on sample density. Solver-integrated SV and the integrated trajectory are independent of sample density, as tested at matching sample times.

conservation() reports total initial volume, maximum total drift and local max|V(t)-V(0)-B*Cumulative(t)|, all in mL. The local residual checks wiring and roundoff; it cannot independently establish integral accuracy. Refinement and different-method tests address that. periodicity() reports per-compartment and maximum final/prior-beat waveform differences in mL, or null for one beat. It imposes no healthy target or automatic convergence gate: a fixed beat count never proves steady state.

Evidence, interpretation and unresolved conflicts

The new four_chamber_m1_manifest validator checks the full model-specific contract against the offline node specification. It rejects reversed topology, wrong/mismatched IDs or valve locations, missing variables, pressure references, properties, units or temporal contexts, and lumen identity assertions. It parses units with pint but requires the exact exported units (no implicit conversion). Cumulative flow is run-integrated volume, SV beat-integrated volume, CO beat-mean flow, and P/V/Q instantaneous. Machine-readable parameter units and state order accompany the contract. Existing registry/bindings are untouched. The default loader uses the bundled physiosim.ontology anatomy JSON through importlib.resources; an explicit local path override remains available. Checkout tests compare its exact bytes with the documentation original, including when testing an installed wheel. No network fallback exists.

Synthetic fixture and execution

synthetic_fixture() copies legacy exploratory ventricular/vascular scalar values without mutating them. All values are test design choices, not fitted, literature-derived or normal physiology. New E_la=.15, E_ra=.10 mmHg/mL, R_venous_return=.05, R_pulmonary_venous=.05 mmHg s/mL are explicit fixture choices. In state order, V0=(10,700,2500,20,10,100,400,20) mL and V_initial=(140,850,3200,60,140,180,490,60) mL. This caller declares 5120 mL. This is no conservative split of the legacy state and no volume is created during integration. The engine does not prescribe any total-volume default.

From the repository with existing dependencies (no install/network required):

.venv/bin/python scripts/run_four_chamber_m1.py --output results/m1-demo
.venv/bin/python -m pytest tests/test_four_chamber_m1_model.py tests/test_four_chamber_m1_simulation.py tests/test_four_chamber_m1_semantics.py tests/test_four_chamber_m1_demo.py -q

The default synthetic demonstration uses 30 beats, 400 samples/beat, DOP853, rtol=1e-9, atol=1e-10 mL and max_step=T/200. --cycles, --samples-per-cycle can override duration/density. --config FILE accepts a synthetic JSON object with required complete parameters and optional simulation (cycles, samples_per_cycle) and solver (method, rtol, atol, max_step) objects. No patient data are supported or authorized. Omitted config solver controls use SolverSettings defaults (max_step=None means T/100), recorded as effective values.

Public Python entry points:

from physiosim.experiments.four_chamber_m1_demo import synthetic_fixture
from physiosim.simulation.four_chamber_m1 import SolverSettings, simulate_m1
p = synthetic_fixture()  # explicitly choose a synthetic fixture
r = simulate_m1(p, cycles=2, samples_per_cycle=80,
                settings=SolverSettings(max_step=p.period/200))
print(r.pressure('la'), r.metrics(), r.conservation(), r.periodicity())

The required --output names a private new/empty caller directory. Existing files are never overwritten. trajectories.csv has time and all eight V/P/Q/cumulative columns, at requested sample times rather than native adaptive nodes. CSV Qcum columns correspond to the manifest's Q_cum_* variables. summary.json contains all parameters, effective numerical settings and metrics; manifest.json contains the checked semantic contract, full config, source/config/output hashes and Python/dependency versions. Source hashes describe the imported runtime modules and bundled anatomy resource with package-relative keys; they do not require repository docs or scripts and are not proof of semantic or physiological validity. Manifest output hashes omit the manifest itself. figure.png and local index.html display the synthetic label and limitations. There are no timestamps; byte replay is tested in the same environment, without claiming bit identity across platforms. Files are mode 600 and output directory mode 700. All payloads, including the figure, hashes, dependency metadata and serialized manifest, are prepared before publication. Plotting uses a separate private temporary cache and restores MPLCONFIGDIR. Generation failure leaves a new destination absent or an existing empty destination empty. Publication uses exclusive no-follow writes relative to the output directory fd and rolls back this call's files on write failure. Nonempty outputs and final symlinks are refused; symlinked ancestors are accepted.

Scope limits and verification handoff

No active atrial contraction, AV delay, inertance, closure regurgitation, FSI, renal/drug/reflex model or clinical validation. Four ideal algebraic diodes cannot claim dynamic valve behavior. This is no Smith/four-chamber reference reproduction. No unconditional R->0 equivalence to the six-compartment model is claimed or used as a gate; that singular limit requires compatible compliance and initial pressures.

TDD RED/GREEN command logs are private files in the task artifacts tdd/ folder; thresholds above were written before the first RED run. Tests cover literal incidence/endpoints and deliberate mutations, parameter shapes/domains, passive laws, a closed-valve constant-elastance matrix-exponential analytic problem, named outputs, pulse detection, equilibrium/chatter, symmetric simultaneous events, positivity/conservation, method/tolerance refinement, sampling/replay, error paths, semantic negatives and demo serialization. These are software/math checks, not physiological validation. The router runs the full legacy suite and fresh cross-provider review separately; this implementation stage does not claim those unrun checks passed.