Exploratory six-compartment cardiovascular model

Scope: executable closed-loop teaching/research prototype, not a clinical model, not a patient-specific prediction, and not a replication of Smith et al. (2004). All numeric physiological defaults below are author-selected exploratory choices. No parameter was fitted to a patient or borrowed as a verified published value. The default run is a computational baseline, not a healthy/normotensive reference.

Source review before implementation

The accessible Physiome CellML encoding was downloaded as XML data and inspected before model implementation. Its own metadata attributes the translation to Matlab code supplied by the original authors.[1] The accompanying reference is Smith BW, Chase JG, Nokes RI, Shaw GM, Wake G, Minimal haemodynamic system model including ventricular interaction and valve dynamics, Medical Engineering & Physics 26 (2004), 131–139, PMID 15036180.[2]

The inspected CellML vena_cava and aorta components use a linear pressure–volume law, P = E_es * (V - V_d); its flow component defines the systemic and pulmonary vascular flows by pressure difference divided by resistance.[1] The ventricular components mix an activated end-systolic pressure with a passive end-diastolic pressure, while additional components describe septal and pericardial interaction.[1] The original model includes an “open on pressure close on flow” valve law with inertia; our simpler pressure-driven ideal diodes deliberately do not reproduce that law.[2]

Our explicit modifications/design assumptions:

Raw evidence is in evidence/a_smith_2004.cellml and evidence/a_smith_overview.html; the former was parsed but never executed. Source identities and verbatim evidence are in physiology_sources.json. No source-model implementation was incorporated into the simulator.

Source identity and license (reviewed 2026-10-31). The parsed capture[1] is a SemSim-annotated copy from PMR workspace 267 (semantic-annotation), not the file behind the Smith exposure. The exposure's own source is a separate workspace at changeset f7b732c9[3][4], retained as evidence/a_smith_2004_canonical.cellml. A static comparison (evidence/a_smith_2004_compare.py, output a_smith_2004_compare.json) finds the same 14 components, 32 equations and 94 variable connections in both, but the workspace-267 capture has no initial_value attributes: 43 parameters and 10 state initial conditions are absent, so it is underdetermined and cannot be simulated as captured. Any reference simulation must use the canonical file. That file's own status note says the beat is cycled by piecewise conditions, so only 14 beats (10.5 s at the 0.75 s period) are encoded.[3]

PMR states that all publicly accessible repository content is licensed under CC BY 3.0 Unported.[4] Both captures are publicly accessible, so both fall under that statement; only the canonical file also has an exposure-specific license page.[4] Redistribution requires attribution to the CellML author (Geoffrey Nunns, Auckland Bioengineering Institute), the original paper (PMID 15036180), the source URL and download time, and the PMR citation (Lloyd et al., Bioinformatics 2008;24(18):2122–2123). The license covers the CellML encodings, not the journal article's text or figures. This is technical due diligence, not legal advice.

Implemented equations

State order COMPARTMENTS = (lv, sa, sv, rv, pa, pv). The circulation is a directed ring:

LV --aortic--> SA --systemic--> SV --tricuspid--> RV
RV --pulmonary_valve--> PA --pulmonary--> PV --mitral--> LV

All six state variables are total compartment volumes, not just stressed volumes. V0 is the unstressed-volume parameter; pressure uses V - V0. These are implementation definitions, not a claim of source-model equivalence:

T = 60 / heart_rate                     [s; HR in beats/min]
phi = (t modulo T) / T                  [dimensionless]
a(phi) = (1 - cos(2*pi*phi/s))/2         if 0 <= phi < s
       = 0                             otherwise
E_lv(t) = emin_lv + (emax_lv - emin_lv)*a(phi)
E_rv(t) = emin_rv + (emax_rv - emin_rv)*a(phi)
P_lv = E_lv(t)*(V_lv - V0_lv)
P_rv = E_rv(t)*(V_rv - V0_rv)
P_i = (V_i - V0_i)/C_i                  for i = sa, sv, pa, pv
Q_valve = max((P_upstream-P_downstream)/R_valve, 0)
Q_bed = (P_upstream-P_downstream)/R_bed

The pulse has value zero at the start/end of systole and peaks at s*T/2. Both ventricular activations share a phase. emax_lv directly controls the LV maximum elastance; this is a proxy intervention, not a calibrated drug effect.

With flows ordered (aortic, systemic, tricuspid, pulmonary_valve, pulmonary, mitral), the ODEs are:

dV_lv/dt = Q_mitral - Q_aortic
dV_sa/dt = Q_aortic - Q_systemic
dV_sv/dt = Q_systemic - Q_tricuspid
dV_rv/dt = Q_tricuspid - Q_pulmonary_valve
dV_pa/dt = Q_pulmonary_valve - Q_pulmonary
dV_pv/dt = Q_pulmonary - Q_mitral

Each flow appears once with each sign, so the symbolic sum of all six derivatives is exactly zero. Numerical conservation is tested separately; volumes are never renormalized to force a passing result. No pressure or volume clipping is used. Valves clip flow only according to their constitutive law.

Complete default parameter provenance

Every entry is exploratory, author-selected, unfitted, not clinically validated. The numerical values below have no claimed literature measurement source. The physiological source citations support equation structure, not these values. Machine-readable entries for every dataclass field are in evidence/a_parameter_provenance.json.

Dataclass field Default Unit Design role
heart_rate 75 beat/min Imposed pacing, no baroreflex
emin_lv 0.06 mmHg/mL Linear passive LV stiffness
emax_lv 2.5 mmHg/mL Peak LV stiffness
emin_rv 0.03 mmHg/mL Linear passive RV stiffness
emax_rv 0.8 mmHg/mL Peak RV stiffness
systolic_fraction 0.4 1 Width of activation pulse / cycle
compliance_sa 1.5 mL/mmHg Systemic arterial reservoir
compliance_sv 100 mL/mmHg Systemic venous reservoir
compliance_pa 5 mL/mmHg Pulmonary arterial reservoir
compliance_pv 20 mL/mmHg Pulmonary venous reservoir
resistance_aortic 0.01 mmHg s/mL Aortic valve
resistance_systemic 1 mmHg s/mL Systemic vascular bed
resistance_tricuspid 0.01 mmHg s/mL Tricuspid valve
resistance_pulmonary_valve 0.01 mmHg s/mL Pulmonary valve
resistance_pulmonary 0.1 mmHg s/mL Pulmonary vascular bed
resistance_mitral 0.01 mmHg s/mL Mitral valve
unstressed_volumes (10, 700, 2500, 10, 100, 400) mL Order lv, sa, sv, rv, pa, pv
initial_volumes (140, 850, 3200, 140, 180, 490) mL Same order; sums to 5000 mL

The initial distribution is an exploratory starting condition, not a periodic solution. The default baseline pressures are elevated; no claim is made that this parameter set is “normal.” Initial conditions and parameter validity checks do not guarantee physical validity for arbitrary user-specified interventions.

Public Python API

from dataclasses import replace
from physiosim.models import Parameters, COMPARTMENTS, FLOW_NAMES
from physiosim.simulation import simulate, SimulationResult

p = Parameters()
baseline = simulate(parameters=p, cycles=40, samples_per_cycle=400,
                    rtol=1e-7, atol=1e-8, max_step=None, method="DOP853")
reduced = simulate(parameters=replace(p, emax_lv=0.5 * p.emax_lv))
print(baseline.metrics())
last = baseline.final_beat
lv_volume_ml = baseline.volumes[last, COMPARTMENTS.index("lv")]

Parameters is a frozen dataclass. Its period property is in seconds. All scalar physiological parameters must be finite/positive; maximum elastance cannot be below minimum; 0 < systolic_fraction < 1. Each volume tuple must have six finite entries (initial volumes positive, unstressed volumes nonnegative).

simulate(parameters=None, cycles=40, samples_per_cycle=400, rtol=1e-7, atol=1e-8, max_step=None, method="DOP853") -> SimulationResult uses scipy.integrate.solve_ivp on smooth valve/activation regimes, as described below. It exposes solver selection directly; Radau was independently exercised in the tests. Integration failure raises RuntimeError. cycles must be an integer >=1, and samples_per_cycle an integer >=4. Tolerances must be positive finite scalars; atol is in mL. Explicit max_step must be positive finite seconds. Its default is T/100. These solver/sampling defaults are numerical design choices, not physiological parameters. No solver termination criterion claims a steady state.

SimulationResult contains:

heart_rate_bpm is the imposed pacing rate, not an estimate from peak detection. stroke_volume_ml is trapezoidal integration of forward aortic flow over the last beat; cardiac_output_l_min is that volume divided by beat duration, converted to L/min. cardiac_output_m3_s supplies the same output in SI units (1 mL = 1e-6 m³, 1 L = 1000 mL, 1 min = 60 s; unit definitions). lv_edv_ml/lv_esv_ml are sampled LV extrema, not independently detected valve event values, and lv_ejection_fraction = (EDV-ESV)/EDV is dimensionless. Thus the flow-based SV and sampled EDV-ESV can differ slightly.

Pressure keys are systemic_systolic_pressure_mmhg, systemic_diastolic_pressure_mmhg, systemic_mean_pressure_mmhg, pulmonary_mean_pressure_mmhg, pulmonary_venous_mean_pressure_mmhg. Means are time-weighted integrals, not unweighted sample averages. volume_drift_ml is the maximum absolute change in total volume across all samples. final_beat_max_volume_difference_ml compares all six last-beat volume waveforms with the prior beat at matched phases; it is NaN for a one-beat run. Consumers writing strict JSON must handle this NaN rather than calling it zero. Sampling resolution affects extrema/quadrature independently of ODE tolerances.

Executed numerical evidence

Historical pre-event-splitting evidence: the measurements in this section and the original evidence captures describe the previous single-solve integrator. They are retained for provenance, not as freshly generated outputs of the current implementation. The equations and acceptance bounds are unchanged; numerical trajectories need not be bitwise identical after the integration fix.

Run python docs/evidence/a_verify_core.py in the project environment to regenerate evidence/a_core_results.json; exact results and library versions are recorded there. A 40-cycle, 400-sample/beat default run produced:

Computed quantity Baseline Half LV peak elastance
HR (beats/min) 75 75
Forward SV (mL) 102.6564 89.3244
CO (L/min) 7.69923 6.69933
LV EDV (mL) 177.734 214.082
LV ESV (mL) 75.1345 124.705
LV EF (fraction) 0.57726 0.41749
Systemic systolic/diastolic pressure (mmHg) 163.009 / 104.702 142.829 / 91.424
Systemic mean pressure (mmHg) 133.498 116.434
Pulmonary arterial mean pressure (mmHg) 23.7631 24.1710
Pulmonary venous mean pressure (mmHg) 10.9381 12.9989
Maximum total-volume drift (mL) 2.01e-11 or less 1.37e-11 or less
Last vs prior beat max volume difference (mL) 0.00666 0.03982

These are simulated outcomes, not external observations. Reduced LV contractility here causes lower output and higher pulmonary venous pressure; the intervention is a new run from the same initial volumes, not a mid-run switch or a clinical heart-failure diagnosis. The baseline meets the deliberately modest test target of less than 0.1 mL last-versus-prior-beat volume difference; this is not a proof of asymptotic stability for all parameter sets.

Tightening to rtol=1e-9, atol=1e-10, max_step=T/200 gives baseline CO 7.69931 L/min and beat difference 0.000222 mL or less. Maximum volume difference between the full default and tight trajectories was 0.3153 mL, including the transient; it must not be described as machine-precision trajectory agreement. The four-cycle DOP853-versus-Radau test, with tighter tolerances, requires each volume sample to agree within 0.002 mL absolute tolerance (plus pytest's default relative allowance) and SV within relative tolerance 1e-4.

Tests and development evidence

tests/test_cardiovascular.py contains constitutive-law, four-diode, six-state mass-balance, conservation, final-beat, metric-quadrature, invalid-input, contractility-response, cross-solver and public-import checks. Eight incremental red→green feature slices were run; logs are stored as evidence/a_tdd_01_red.txt through a_tdd_08_green.txt. Later response and solver comparisons are acceptance/regression tests against already implemented behavior, not evidence of clinical validation. That historical feature suite returned 25 passed. Current portability regressions are described below; fresh test results are retained by CI.

Limitations and next validation work

No reference trajectory was reproduced, no original model code was executed, and no patient or experimental data was used. The pressure baseline is elevated; parameter tuning to a prespecified physiological dataset would be separate work, not a reason to relabel the present simulation as validated. Valve switching is nonsmooth, so tolerances and output sampling need convergence checks. Neither sampling nor default solver settings guarantee accurate valve-opening times. The fixed linear pressure law admits unphysical negative pressures for some parameter/initial-state combinations; these are not hidden by clipping. Users must inspect positivity, conservation, beat convergence and intervention ranges.

Sources

[1] https://models.physiomeproject.org/workspace/267/rawfile/6ae217019bf59fc1e22e2dc5235751c6fcf6be24/Smith_2004.cellml — Smith 2004 CellML encoding [2] https://models.physiomeproject.org/exposure/9d046663ba5cac5c8a61ac146183614b/view — Physiome Smith 2004 overview [3] https://models.physiomeproject.org/workspace/smith_chase_nokes_shaw_wake_2004/rawfile/f7b732c9707abdba5a55d471c49baf7dee92b036/smith_chase_nokes_shaw_wake_2004.cellml — Smith 2004 canonical CellML encoding [4] https://models.physiomeproject.org/exposure/9d046663ba5cac5c8a61ac146183614b/smith_chase_nokes_shaw_wake_2004.cellml/license_citation — PMR license and citation page

Solver-integrated cumulative flows (opt-in)

With simulate(..., cumulative_flows=True), the solver augments the six volume states with six directed-edge states

[ C_k(t)=\int_0^t Q_k(t')\,dt', \qquad \dot C_k=Q_k, ]

where flow is in mL/s and cumulative flow is in mL. Edge i is the outflow of compartment i, and edge i-1 (modulo six) is its inflow. The scalar absolute tolerance, in mL, applies to all 12 states. The default remains six volume states and returns no cumulative-flow array.

Integration across valve transitions

The physical pressure and ideal-diode flow laws above are unchanged. Both six-state and augmented solves now use fixed valve regimes. Within a regime, an open valve uses its signed pressure difference divided by resistance and a closed valve has zero flow. Terminal pressure-gap events locate the first opening or closure. A smooth continuation beyond an event may be evaluated by the solver while finding the root, but only the trajectory through that root is retained. The next solve starts in the new regime. Dense output therefore does not interpolate across the ideal-diode corner. Integration also restarts at known systole/diastole boundaries of the activation pulse. The pulse peak is also an integration checkpoint: a large closed-valve step can otherwise start and end with a negative pressure gap while skipping an entire intervening opening and closure. This checkpoint preserves the user controls and requires no trajectory projection or change to the flow law.

For the augmented solve, each regime starts six local flow integrals at zero. Their endpoint increments are added to the running cumulative offsets. rtol, atol, max_step, output sampling, parameters and reported units are unchanged. Error control thus uses local increments instead of an ever-growing cumulative scale. Volumes are neither projected nor renormalized, and sampled cumulative flows are not clipped or replaced by post-hoc quadrature.

At roundoff-scale pressure ties, a short forward Euler probe determines the right-hand valve mode only; it never advances the integrated state. The tie resolution includes pressure arithmetic and a few ulps of event-time error multiplied by the estimated pressure-gap slope. Simultaneous transitions and zero-flow equilibria have dedicated regressions. Repeated zero-time events raise an error rather than silently skipping time.

The original two acceptance tests remain unchanged: four-cycle augmented/plain volume agreement within 1e-4 mL absolute, and 40-cycle tight/fine cumulative stroke-volume agreement within 1e-5 mL absolute, both with zero relative allowance. tests/test_hybrid_integration.py additionally exercises alternate dot-product reductions and an algebraically equivalent activation formula, conservation, simultaneous transitions, zero-flow equilibrium and independence from output sampling. Six additional large-step cases cover LV/RV pulses at three arterial-pressure levels, using the same 1e-4 mL volume and 1e-5 mL cumulative-flow absolute bounds. These tests do not establish accuracy for all parameter sets or clinical validity. A small balance residual still checks linear incidence wiring, not independent quadrature accuracy.

The implementation uses the public solve_ivp terminal-event and dense-output interfaces, without SciPy internals or dependency changes: https://docs.scipy.org/doc/scipy-1.17.0/reference/generated/scipy.integrate.solve_ivp.html

Historical measurements before event splitting

All values and limitations in the remainder of this cumulative-flow section were measured with the previous single-solve integrator and are preserved as historical evidence. They are not current-version results.

At rtol=1e-9, atol=1e-10, and max_step=T/200, a four-cycle augmented run differed from the six-state volume trajectory by at most 2.28515e-5 mL. In a 20-cycle run, the maximum independent incidence-matrix balance residual was 9.77707e-12 mL; swapping two incidence columns produced 189.025 mL. This small correctly wired residual is not evidence that the cumulative-flow quadrature is accurate: Runge-Kutta (and linear multistep) methods preserve the linear invariant V_i - V_i(0) - (C_in - C_out). Here dV/dt and dC/dt are built from the same evaluated flow vector and DOP853 dense output is linear in the stage values, so the invariant also holds at interpolated t_eval samples, up to a roundoff floor of order eps*|C|. The residual was ~1e-11 mL at rtol 1e-3, 1e-7 and 1e-9 alike (independent review R1), confirming that it checks incidence/sign wiring and roundoff only. Cumulative-flow accuracy must be demonstrated separately by tolerance refinement.

For a 40-cycle baseline, cumulative aortic stroke volume was 102.599935089 mL at those tight settings and 102.599933804 mL at rtol=1e-11, atol=1e-12, and max_step=T/400, an absolute difference of 1.28573e-6 mL. Tight-setting sampled trapezoidal values were 102.657489315 mL at 400 samples/beat and 102.598919777 mL at 1600 samples/beat; their absolute differences from the integrated value were 0.0575542 mL (0.0560958%) and 0.00101531 mL (0.000989583%), respectively. The six final-beat edge throughputs spanned 1.14729e-5 mL, within the 2.39901e-5 mL bound derived from the observed compartment-wise final-beat volume changes; this follows from the same linear invariant and is a consistency check, not independent accuracy evidence.

Known limitations of the augmented mode (measured; reviewer R1 numbers re-executed by the integrator, 40-cycle baseline, fine reference rtol 1e-11, atol 1e-12, T/400):

Strict multi-beat periodicity report

physiosim.validation.periodicity_report(volumes, samples_per_cycle, beats=3, tolerance_ml=1e-4) compares each of the last beats beats with its predecessor at identical phase samples (both beat endpoints included) and returns per-beat residuals in mL, oldest first. The residual for the last beat equals metrics()['final_beat_max_volume_difference_ml'] exactly. With fewer than beats + 1 complete beats it returns available=False and never passes. Passing is a numerical settling check, not biological validation, and not proof of a unique limit cycle. It is not yet wired into the runner's exit status; the declared 0.1 mL last/prior-beat milestone gate is unchanged.

Historical pre-event-splitting measurements, not re-executed here: three canonical scenarios (60 cycles, 400 samples/beat, DOP853), three successive beats, 1e-4 mL:

Scenario six-state, rtol 1e-9/atol 1e-10/T/200 augmented (cumulative_flows), same augmented, rtol 1e-11/atol 1e-12/T/400
baseline 2.33e-4, 7.37e-5, 2.29e-5 — FAIL 1.40e-5, 2.40e-5, 1.08e-5 — pass 3.3e-7, 1.5e-7, 1.3e-7 — pass
reduced contractility 9.42e-6, 7.39e-6, 9.57e-6 — pass 1.83e-5, 2.09e-5, 2.42e-5 — pass 7.2e-8, 1.4e-7, 1.5e-7 — pass
partial restoration 2.22e-5, 1.94e-5, 9.26e-6 — pass 4.29e-4, 8.89e-4, 4.86e-4 — FAIL 3.8e-7, 1.8e-7, 6.1e-7 — pass

The historical six-state baseline values reproduce those previously reported by the independent reviewer. At the canonical tolerances the strict verdict changes when only the error-control state set changes, and residuals are not monotone, so residuals of 1e-5 to 1e-3 mL there are dominated by integration error rather than physiological settling. At the fine settings all three scenarios pass with residuals <= 6.1e-7 mL. Strict-periodicity claims should use the fine settings (or a demonstrated refinement sequence), not the canonical tolerances.